Standards · Performance classes
Wind classes and g tot: two scales for comparing zip screens
This article is compiled from official statistics, regulations, standards and industry publications; sources are listed at the end.
- European standards turn two key properties of external shading, wind resistance and solar heat control, into classes that can be compared across manufacturers [1, 2].
- The EN 13561 wind scale now runs from class 0 to class 6, after an extension in 2019 prompted by more resistant products [1].
- For solar control, the reference value is g tot under EN 14501; the smaller it is, the less solar heat reaches the room [2].
- Beaufort figures quoted alongside the classes are approximations that vary by product type and manufacturer [3].
Describing a zip screen as “wind resistant” or a blind as “cooling” gives a buyer nothing to compare. Performance classes do: they turn both claims into values measured by a common method, so that products from different manufacturers can be set side by side in a tender. This article explains the two scales that matter most for external shading, wind resistance and total solar energy transmittance, and what to look for when reading them in a declaration of performance or a datasheet.
For more information, contact Ferrini: +90 232 864 22 20 · info@ferrini.com.
Wind resistance: classes 0 to 6
EN 13561 groups external blinds and awnings into wind resistance classes, each starting at a defined nominal wind pressure expressed in N/m² [1]. The top three classes were added by a Commission delegated regulation in 2019 to take account of the more resistant products then on the market [1]. The wind load test behind any declared class follows EN 1932 [4].
For exposed products such as zip screens, awnings and external venetian blinds, the wind class is often the figure that decides between two offers. In Europe, wind resistance is one of the main directions in which zip screens are being developed [5, 6].
Solar control: what g tot tells you
g tot expresses how much of the incoming solar energy gets through the glazing and the shading product combined [2]. Because it is a combined value, the contribution of a screen depends on the glass behind it, so declared figures from different suppliers are only comparable when they refer to similar glazing.
The value also travels beyond the datasheet. In about two thirds of European countries, the national method for calculating a building’s energy performance takes the EN 14501 g tot as an input, so a declared figure can feed straight into a project’s energy assessment [7].
What to compare between offers
It helps to request the same set of values from every supplier: the declared wind class under EN 13561 together with its EN 1932 test basis, the g tot with the glazing it refers to, and the visual comfort classes wherever view or glare matters. Values given only in a brochure, without a declaration of performance behind them, are difficult to compare and should be treated with caution.
Frequently asked questions
Which wind class is enough?
There is no single answer: the class needed depends on where the screen will be installed and on what the manufacturer declares within the EN 13561 scale of 0 to 6 [1]. Write the declared class into the specification; a Beaufort number may correspond to different classes depending on product type and manufacturer [3].
Do shutters and external venetian blinds use the same wind scale?
They fall under a different product standard, EN 13659, which defines a similar classification [8]. The wind load test for both families follows EN 1932 [4]. Where a project combines zip screens with roller shutters or external venetian blinds, each product’s class should be read under its own standard rather than carried over from the other.
Does EN 14501 cover anything besides heat?
Yes. Its visual comfort classes cover blackout, privacy at night, visual contact with the outside, glare control and the use of daylight [2]. For a zip screen, these classes help weigh solar control against view and daylight, which often matter to occupants as much as summer temperatures do.
Sources
- European Commission, Commission Delegated Regulation (EU) 2019/1188 – classes of performance for resistance to wind load of external blinds (EN 13561), OJ L, 12.07.2019. https://eur-lex.europa.eu/eli/reg_del/2019/1188/oj
- CEN, EN 14501:2021 Blinds and shutters – Thermal and visual comfort – Performance characteristics and classification (consolidated version EN 14501:2021+A1:2025), March 2021; 2025. https://iteh.es/catalog/standards/cen/8b0257b8-f10b-4994-ae49-2493d6cd12ab/en-14501-2021
- BauNetz Wissen Sonnenschutz (Heinze GmbH), Windwiderstandsklassen, undated page, accessed 02.10.2026. https://www.baunetzwissen.de/sonnenschutz/fachwissen/bauphysik/windwiderstandsklassen-10299092
- CEN / Estonian Centre for Standardisation; Swiss Association for Standardization, EN 12045:2000 Power operated blinds and shutters – Safety in use; EN 1932:2013 External blinds and shutters – Resistance to wind loads, catalogue records, accessed 02.10.2026. https://www.evs.ee/en/evs-en-12045-2000
- Renson, About Renson, undated page, accessed 02.10.2026. https://www.renson.net/en-gb/about-renson
- Renson, Fixscreen 100 product page, undated page, accessed 02.10.2026. https://www.renson.eu/es-es/producten-zoeken/zonwering/screens/fixscreen/fixscreen-100
- Van Eycken, A. (ES-SO), Solar and daylight management for energy performance of buildings, REHVA Journal 04/2015, s. 26–27. https://rehva.eu/rehva-journal/chapter/solar-and-daylight-management-for-energy-performance-buildings
- CEN (European Committee for Standardization), CEN/TC 33, EN 13561:2015 External blinds and awnings; EN 13659:2015 Shutters and external venetian blinds – Performance requirements including safety, August 2015 (catalogue records). https://iteh.es/catalog/standards/cen/49186b1d-7c1a-4bbc-9a04-f83572642c33/en-13659-2015